Thickness range from 1.2 to 25 mm

Architectural Glass · 01
Tempered Glass for Architectural Projects
Drawing-based tempered glass production for façades, doors, windows, balustrades, canopies and partitions.
Product Overview
Capabilities Confirmed for Project Review
WJ supplies tempered glass for building applications in thicknesses from 1.2 to 25 mm. Glass below 4 mm is handled through chemical tempering according to the supplied capability information.
Clear, ultra-clear, Low-E and coated glass options can be processed, with project shapes and fabrication completed from customer drawings before tempering.
Maximum confirmed size of 10 m × 3.3 m
Clear, ultra-clear, Low-E and coated glass options
Shaped glass processing supported
Heat Soak Test available
Production from CAD, DXF or customer drawings
Available Configurations
Specified Tempered Glass Options
The options below are limited to the configurations confirmed in the supplied production capability information.
Technical Capabilities
Confirmed Production Parameters
Final suitability is reviewed against the full glass make-up, drawing and project specification.
Custom Processing
Confirmed Processing Options
Processing is confirmed against the selected glass type, dimensions and final make-up.
Applications
Project Uses Confirmed in the Capability Sheet
Only the applications expressly confirmed in the supplied product information are listed.
Façades
Doors & Windows
Balustrades
Canopies
Partitions
Project Customization
Produce from Your Drawings
Tempered glass can be produced from CAD files, DXF files or customer drawings. Hole positions, edge distances and processing details are reviewed against the glass thickness before confirmation.
Standards & Certifications
Available Documentation
- Product test reports are available.
- A CCC test report is available.
Documentation is matched to the selected product configuration and should be confirmed before order placement.
Product Test & Certification Documentation
Tempered Glass — CCC Certificate Scope
The supplied China Compulsory Certification (CCC) document identifies architectural tempered glass manufactured to GB 15763.2-2005. The certificate appendix specifies the following product scope.
| Item | Documented Scope / Result |
|---|---|
| Certificate number | 2018051302026540 |
| Standard stated on certificate | GB 15763.2-2005 |
| Thicknesses listed in appendix | 8 mm, 10 mm and 12 mm |
| Maximum developed area in appendix | 8.93 m² for each listed thickness |
| Maximum bow height in appendix | 0 mm (flat glass) |
| Minimum adjacent-edge angle in appendix | 30° |
| Glass options within the stated scope | Body-tinted or coated glass is included within the appendix parameter limits. |
| Printed issue / expiry dates | 6 June 2023 / 5 June 2028 |
These are certificate-scope limits, not a replacement for the production capabilities above. Certificate validity is subject to surveillance and current status confirmation. Request the applicable manufacturing certificate and confirm the proposed configuration before ordering.
Request Applicable Documentation →Material knowledge
Choose the Right Construction for Your Project
Thermal tempering changes the stress distribution within glass. It is selected where the design requires increased mechanical strength or a safety breakage pattern, but it does not keep a broken pane in place in the way a suitable laminated construction can.
What to confirm before ordering
- Complete the cutting, holes and edge details before tempering; changes after heat treatment normally require a replacement pane.
- Specify the support system, loading and applicable safety requirements rather than choosing thickness by appearance alone.
- Discuss visual acceptance criteria, including roller-wave distortion and the viewing conditions for large glazed areas.
Frequently Asked Questions
Can tempered glass be cut or drilled after manufacture?
No. Confirm the final drawing before heat treatment. Site adjustments to size or hole positions should not be planned after tempering.
Does tempering replace lamination?
No. Tempering and lamination address different requirements and can be combined. Where post-breakage retention matters, the complete glass and support assembly needs review.
What should I send for a quotation?
Send panel dimensions, thickness, quantity, edge finish, hole and cut-out drawings, intended application and destination.
Related Glass Solutions
Laminated Glass
PVB, SGP and EVA laminated glass in double, triple and multi-layer make-ups, including curved and decorative options.
Explore Laminated Glass →Insulating Glass Units (IGU)
Double and triple IGUs with Low-E, tempered, laminated, ultra-clear and argon-filled configurations.
Explore Insulating Glass Units →Heat-Strengthened Glass
Heat-strengthened glass from 4–25 mm for laminated, IGU and Low-E make-ups, with confirmed pre-processing options.
Explore Heat-Strengthened Glass →Request a Quote
Start Your Enquiry
Tempered Glass RFQ
Send us your glass specifications or project drawings for quotation.
Include the glass make-up, dimensions, quantity, processing details, required documentation and delivery destination.