Contemporary façade built with large coated architectural glass panels

Architectural Glass · 08

Coated and Solar Control Glass for Project Façades

Online and offline coated glass processed to consultant specifications, with configuration-specific performance data.

Product Overview

Capabilities Confirmed for Project Review

WJ supplies online and offline coated glass, including solar-control options, in confirmed thicknesses from 4 to 25 mm. Tempered, laminated, insulating and ultra-clear-substrate configurations are supported.

VLT, solar transmittance, reflectance, SHGC and U-value data can be provided for the selected configuration, and production can follow curtain wall consultant technical specifications.

01

Online and offline coating options

02

Thickness range from 4 to 25 mm

03

Tempered, laminated and IGU processing supported

04

Ultra-clear substrate available

05

Configuration-specific VLT, SHGC, U-value and reflectance data

06

Same-batch colour consistency control

Available Configurations

Specified Coated & Solar Control Glass Options

The options below are limited to the configurations confirmed in the supplied production capability information.

01Online coated glass
02Offline coated glass
03Solar control glass
04Tempered coated glass
05Laminated coated glass
06Coated insulating glass units
07Ultra-clear coated glass

Technical Capabilities

Confirmed Production Parameters

Final suitability is reviewed against the full glass make-up, drawing and project specification.

ParameterConfirmed Capability
Thickness Range4–25 mm
Maximum SizeContact us for project-specific specifications.
Glass OptionsOnline, offline and solar-control coatings; ultra-clear substrate available
Processing OptionsTempering, laminating, insulating assembly and edge deletion
Available ConfigurationsMonolithic, laminated and insulating coated glass
Performance DataVLT, solar transmittance, reflectance, SHGC and U-value can be provided by configuration
Edge DeletionRequired for the stated processing; equipment is available
Colour ControlSame-batch colour consistency can be controlled
Cross-Batch Colour DifferenceContact us for project-specific specifications.

Custom Processing

Confirmed Processing Options

Processing is confirmed against the selected glass type, dimensions and final make-up.

01Tempering
02Laminating
03Insulating glass assembly
04Ultra-clear substrate processing
05Edge deletion

Applications

Project Uses Confirmed in the Capability Sheet

Only the applications expressly confirmed in the supplied product information are listed.

01

Curtain Wall Projects

02

Consultant-Specified Façade Packages

Project Customization

Produce to Curtain Wall Consultant Specifications

Coated and solar-control glass can be produced to the technical specification issued by the curtain wall consultant. Share the selected coating, glass make-up and required performance data for review.

Recommended enquiry inputs
01Curtain wall consultant specification
02Coating and glass make-up
03Required VLT, SHGC, U-value or reflectance

Standards & Certifications

Available Documentation

  • A CCC test report is available.

Documentation is matched to the selected product configuration and should be confirmed before order placement.

Material knowledge

Choose the Right Construction for Your Project

Solar-control glazing manages incoming solar energy while contributing to façade appearance and daylight. Reflectance, transmission and thermal insulation are separate selection criteria. The right specification considers the building orientation and complete glazing assembly.

What to confirm before ordering

  • Request performance information for the final assembly, not a different reference thickness.
  • Review internal and external appearance in representative lighting.
  • Assess thermal-stress risks and compatible heat treatment with the project team.

Frequently Asked Questions

Does reflective glass provide privacy at night?

Not reliably. Visibility depends on the lighting on each side. Consider a separate privacy solution where night-time privacy is required.

Is solar-control glass used for photovoltaic modules?

That is a different product requirement. Architectural solar control limits unwanted gain; photovoltaic cover glass is selected for energy transmission and module compatibility.

Does a darker colour always mean better insulation?

No. Compare the declared thermal and solar values of the complete make-up rather than judging by colour.

Related Glass Solutions

Low-E Glass

Online and offline Low-E glass with single, double and triple silver options for tempered, laminated and IGU configurations.

Explore Low-E Glass →

Request a Quote

Start Your Enquiry

Project information
Drawings, glass schedules, artwork or reference images. PDF, DWG, DXF, JPG, PNG, XLS or XLSX; up to 5 files and 3 MB total.

Secure upload: Selected files are submitted directly with your enquiry. You may upload up to 5 files with a combined size of 3 MB.

Secure online submission is enabled.

Coated & Solar Control Glass RFQ

Send us your glass specifications or project drawings for quotation.

Include the glass make-up, dimensions, quantity, processing details, required documentation and delivery destination.

WhatsApp